feat add modbus tcp protocol for control framework

This commit is contained in:
Liu_Weichao
2022-12-13 11:19:11 +08:00
parent 9b334f90e0
commit 56a014fe98
13 changed files with 855 additions and 34 deletions
@@ -18,6 +18,47 @@
* @date 2022.9.27
*/
#include <control.h>
extern int Adapter4GActive(void);
void ControlFx3uTest(void)
{
int i, j = 0;
int read_data_length = 0;
uint8_t read_data[128] = {0};
#ifdef CONNECTION_ADAPTER_4G
Adapter4GActive();
#endif
ControlProtocolType modbus_tcp_protocol = ControlProtocolFind();
if (NULL == modbus_tcp_protocol) {
printf("%s get modbus tcp protocol %p failed\n", __func__, modbus_tcp_protocol);
return;
}
printf("%s get modbus tcp protocol %p successfull\n", __func__, modbus_tcp_protocol);
if (CONTROL_REGISTERED == modbus_tcp_protocol->protocol_status) {
ControlProtocolOpen(modbus_tcp_protocol);
for (;;) {
read_data_length = ControlProtocolRead(modbus_tcp_protocol, read_data, sizeof(read_data));
printf("%s read [%d] modbus tcp data %d using receipe file\n", __func__, i, read_data_length);
if (read_data_length) {
for (j = 0; j < read_data_length; j ++) {
printf("j %d data 0x%x\n", j, read_data[j]);
}
}
i++;
memset(read_data, 0, sizeof(read_data));
PrivTaskDelay(10000);
}
//ControlProtocolClose(modbus_tcp_protocol);
}
}
PRIV_SHELL_CMD_FUNCTION(ControlFx3uTest, Mitsubishi fx3u Demo, PRIV_SHELL_CMD_MAIN_ATTR);